Thermoelectric unit

Thermoelectric Cooling Unit

(COLTEC series)

Certificates

  • CE Compliant
f-10-1

Application

Thermoelectric Cooling Units are used for the most demanding industries such as industrial and electronic enclosures, medical equipment, laboratory instruments, aerospace, semiconductors & telecommunications equipment. Uses range from simple food and beverage coolers for an afternoon picnic to extremely sophisticated temperature control systems in missiles and space vehicles. A thermoelectric cooling unit permits the lowering of the temperature of an object below ambient temperature as well as stabilizing the temperature of objects above ambient temperature. A thermoelectric cooler is different from a heat sink because it provides active cooling, unlike a heat sink, which provides only passive cooling. Ariel Technology Inc. provides a variety of solutions for different application as follows:
– Air to Air Thermoelectric Cooling unit (COLTECN series) Telecommunication Battery Temperature Control, Industry Equipment Power Cabinet Cooling, etc.
– Air to Plate Thermoelectric Cooling unit (COLTECAP series) Medical Devices, Instrument and Laboratory Test Equipment, Direct Contact Cooling Design, etc.
– Air to Liquid Thermoelectric Cooling unit (COLTECAL series) Medical Hairdressing Devices, Laser Equipment, or other needed cooling device applications.
– Liquid to Liquid Thermoelectric Cooling unit (COLTECLL series) LED Manufacturing Evaporating Systems, Analytic Instruments, etc.

Features

• Zero maintenance, no filters, compressors, or refrigerant required
• Safe for the environment
• No air exchange between ambient and cabinet air
• Continuous worry-free operation
• Installs vertically or horizontally. Can be installed on any plate thickness by means of screws
• Uses quality ball bearing fans
• Standard direction airflow
• Ingress Protection is NEMA 12/ IP 55

Color

  • RAL 9003 – White

Advantages

Thermoelectric Cooling Units have no moving parts and do not require the use of chlorofluorocarbons. Therefore, they are safe for the environment, reliable, and virtually maintenance-free. They can be operated in any orientation and are ideal for cooling devices that might be sensitive to mechanical vibration. Their compact size also makes them ideal for applications that are size or weight limited, and where even the smallest compressor would have excess capacity.

Air to Air Thermoelectric Cooling Unit (COLTECN series)

Ambient Temp. Range
Weight
Dimensions
Stable Current
Voltage
Cooling Capacity
Model
(°F)
(°C)
(Ib)
(Kg)
(Inch)
(mm)
(A)
(Vdc)
(W-BTU/hr) 
 
14 TO +140
­-10 TO +60
1.32
0.6
4.76×3.94×3.15
121x100x80
2.2 ±10%
12
19-65
COLTECN01512-55
14 TO +140
­-10 TO +60
1.32
0.6
4.25X3.94X3.15
108X100X80
2.5 ±10%
12
25-85
COLTECN02512-55
14 TO +140
­-10 TO +60
2.43
1.1
5.67X4.73X4.05
144X120X103
3.9 ±10%
12
35-120
COLTECN03512-55
14 TO +140
­-10 TO +60
3.97
1.8
6.3X4.8X5.8
162X122X146
8.2 ±10%
12
50-170
COLTECN05012-55
14 TO +140
-­10 TO +60
3.97
1.8
6.30X4.80X5.5.8
160X122X146
4.0 ±10%
24
50-170
COLTECN05024-55
14 TO +140
-­10 TO +60
6.17
2.8
9.49X6.14X8.27
241X156X210
5.0 ±10%
24
80-270
COLTECN-08024-55
14 TO +140
-­10 TO +60
6.17
2.8
9.49X6.14X8.27
241X156X210
12.6 ±10%
12
100-340
COLTECN10012-55
14 TO +140
-­10 TO +60
4.4
2
7.87×7.09×6.38
200X180X162
7.7 ±10%
24
100-340
COLTECN10024-55
14 TO +140
­-10 TO +60
4.4
2
7.87×7.09×6.38
200x180x162
4.3 ±10%
48
100-340
COLTECN10048-55
14 TO +140
-­10 TO +60
16.53
7.5
15.75X7.87X7.09
400X200X180
12.5±10%
24
200-680±10%
COLTECN20024-55
14 TO +140
-­10 TO +60
16.53
7.5
15.75X8.11X7.09
400X206X180
7.5 ±10%
48
200-680 ±10%
COLTECN20048-55
14 to +140
-10 to +60
22
10
11.81×12.99×7.87
300x330x200
15 ±10%
24
300-1024 ±10%
COLTECN30024-55
14 to +140
-10 to +60
22
10
11.81×12.99×7.87
300x330x200
14 ±10%
48
300-1024 ±10%
COLTECN30048-55
14 to +140
-10 to +60
22
10
11.81×12.99×7.87
300x330x200
14 ±10%
48
300-1024 ±10%
COLTECN30048-55
14 to +140
-10 to +60
33
15
15.75×12.99×7.87
400x330x200
14 ±10%
24
400-1365 ±10%
COLTECN40024-55
14 to +140
-10 to +60
33
15
15.75×12.99×7.87
400x330x200
14 ±10%
48
400-1365 ±10%
COLTECN40048-55
14 to +140
-10 to +60
33
15
15.75×12.99×7.87
400x330x200
14 ±10%
48
400-1365 ±10%
COLTECN40048-55
14 to +140
-10 to +60
40
18
15.75×12.99×7.87
400x330x200
5.3 ±10%
48
400-1365 ±10%
COLTECN400240-55
14 to +140
-10 to +60
77
35
2661×17.32×7.09
676x440x180
14 ±10%
48
800-2730 ±10%
COLTECN80048-55
14 to +140
-10 to +60
77
35
2661×17.32×7.09
676x440x180
4.4 ±10%
240
800-2730 ±10%
COLTECN800240-55

Air to Plate Thermoelectric Cooling Unit (COLTECAP series)

Ambient Temp. Range
Weight
Dimensions
Stable Current
Voltage
Cooling Capacity
Model
(°F)
(°C)
(Ib)
(Kg)
(Inch)
(mm)
(A)
(Vdc)
(W-BTU/hr)
 
32 to +140
0 TO +60
1.76
0.8
4.80X3.94X3.23
122X100X82
4.1 ±10%
12
42-145
COLTECAP04012
32 to +140
0 TO +60
2.43
1.1
6.30×4.80×3.23
160x122x82
8.5 ±10%
12
50-170
COLTECAP05012
32 to +140
0 TO +60
2.43
1.1
6.30×4.80×3.23
160x122x82
4.3 ±10%
24
50-170
COLTECAP05024
32 to +140
0 TO +60
7.94
3.6
7.99×6.10×4.98
203x155x152
4.3 ±10%
24
80-270
COLTECAP08024
 

Air to Liquid Thermoelectric Unit (COLTECALseries)

Ambient Temp. Range
Weight
Dimensions
Stable Current
Voltage
Cooling Capacity
Model
(°F)
(°C)
(Ib)
(Kg)
(Inch)
(mm)
(A)
(Vdc)
(W-BTU/hr)
 
14 to +131
­-10 TO +55
3.30
1.5
6.30X4.7X3.3
160X120X84
8.0 ±10%
12
50-170
COLTECAL05012
14 to +131
-­10 TO +55
3.30
1.5
6.30X4.7X3.3
160X120X84
4.0 ±10%
24
50-170
COLTECAL05024
14 to +131
-­10 TO +55
6.83
3.1
7.99×6.10×5.8
203x155x147
5.1 ±10%
24
80-270
COLTECAL08024
14 to +131
-­10 TO +55
6.83
3.1
7.99×6.10×5.8
203x155x147
14.3 ±10%
12
100-340
COLTECAL10012
14 to +131
­-10 TO +55
3.96
1.8
8.66X6.10X3.8
124X122X97
5.7 ±10%
24
100-340
COLTECAL10024
14 to +131
­-10 TO +55
6.83
3.1
6.3X6.1X5.9
160X155X150
8.2 ±10%
24
150-510
COLTECAL15024
14 to +131
-­10 TO +55
10.91
5.0
10.83X6.34X6.34
275X161X161
14 ±10%
24
300-1025
COLTECAL30024

Liquid to Liquid Thermoelectric Cooling Unit (COLTECLL series)

Ambient Temp. Range
Weight
Dimensions
Stable Current
Voltage
Cooling Capacity
Model
(°F)
(°C)
(Ib)
(Kg)
(Inch)
(mm)
(A)
(Vdc)
(W-BTU/hr)
32 to +140
0 TO +60
2.65
1.2
7.87×1.42×2.36
200x36x60
4.2
24
80-270
COLTECLL08024
32 to +140
0 TO +60
8.16
3.7
9.45×4.00×2.36
240x102x60
13.3
24
320-1090
COLTECLL32024