Fan Filters

FTEC series

Certificates

  • UL and cUL Listed, File Number E497874
  • CSA and CSAus Listed, File Number 80030884
  • CE Compliant

 

Application

FTEC10 series Fan Filter and Exhaust Filter are designed to supply forced convection filtered air for enclosures and electrical panels. By using the unique filtering and cooling features, FTEC will cool down the inside of enclosures to a desired temperature to protect the electrical and electronic parts against heat.

 Features  

  • Type 12 and Type 3R NEMA Rating-NO HOOD REQUIRED
  • IP 54 using G3 filter mat and IP 55 using G4 filter mat
  • 115 VAC, 230 VAC, 12, 24, and 48 VDC available
  • Polyurethane sealing gasket
  • Ball bearing Fan
  • Easily snaps into place without the use of screws
  • Washable and reusable filter mat
  • Robust flame-retardant plastic housing, UL 94-V0
  • UV Resistant

 

 Colors   

  • RAL 7035 – Light Gray
  • RAL 7032 – Dark Gray
  • RAL 9011 – Black
  • Other colors on request

Specifications

Mounting Snaps into place without using any screws
Cooling Capacity Airflow from 12 CFM to 450 CFM – 20 m³/hr to 750 m³/hr
Operating Temperature -20 °C to +70 °C
Storage Temperature -20 °C to +70 °C
Ingress Protection According to ANSI 60529
IP 54 using G3 filter mat (Standard)
IP 55 using G4 filter mat (Optional)
NEMA Rating Type 12 for Indoor application
Type 3R for Outdoor application
Material PC/ABS: Flame retardant, UL 94-V0 for Indoor applications
PC: Flame retardant, UL 94-V0 for Outdoor applications
Color Standard colors are RAL 7035 light grey, RAL 7032 dark grey & Black.
Optional colors are available upon request.
Air Flow Direction From outside to the inside of the enclosure (Standard).
Reverse flow direction (Optional).
Filter Mat According to EN 779 classification
G3 filter mat is for IP 54 filter (Standard).
G4 filter mat is for IP 55 filter (Optional).
The filter mats are made of high-performance nonwovens produced from elastic, break-resistant polyolefin fibers with thermal bonding.
The filter mats are cleaned easily by washing, beating or spraying, and can be reused. even after washing, the filter mats remain dimensionally stable, thus retaining their technical filtering properties. The fire class remains unaltered.
Sealing Polyurethane sealing gasket
Fan Bearing Ball-bearing (Standard)
Sleeve bearing (Optional)

FTEC series Part Number ID Chart

1 Size 2 Color
10= 116×116 mm² (4.57″x4.57″) L= RAL 7035
16= 160×160 mm² (6.30″x6.30″) D= RAL 7032
20= 206×206 mm² (8.11″x8.11″) O= OPTIONAL
26= 260×260 mm² (10.24″x10.24″)
32= 326×326 mm² (12.83″x12.83″)
3 INGRESS PROTECTION 4 NEMA RATING
4= IP 54 X= TYPE 12
5= IP 55 Z= TYPE 3R-No Hood required
5 VOLTAGE 6 FLOW DIRECTION
12D= 12 VDC S= STANDARD
24D= 24 VDC R= REVERSE
48D= 48 VDC
115= 115 VAC
230= 230 VAC
7 BEARING TYPE 8 FAN SIZE
B= BALL BEARING S= SMALL
S= SLEEVE BEARING BLANK= STANDARD
M= MEDIUM
B= BIG
FTEC26L4X-115SBS
FAN FILTER, 260X260, RAL 7035, IP 54, TYPE 12, 115 V (50/60 HZ), STANDARD FLOW DIRECTION, BALL BEARING, WITH SMALL FAN